Airway and Respiratory Devices

By

Vanessa Moll

, MD, DESA, Emory University School of Medicine, Department of Anesthesiology, Division of Critical Care Medicine

Last full review/revision Apr 2020| Content last modified Apr 2020
Click here for Patient Education
Topic Resources

If no spontaneous respiration occurs after airway opening Clearing and Opening the Upper Airway Airway management consists of Clearing the upper airway Maintaining an open air passage with a mechanical device Sometimes assisting respirations (See also Overview of Respiratory Arrest.) read more and no respiratory devices are available, rescue breathing (mouth-to-mask or mouth-to-barrier device) is started; mouth-to-mouth ventilation is rarely recommended. Exhaled air contains 16 to 18% oxygen and 4 to 5% carbon dioxide, which is adequate to maintain blood oxygen and carbon dioxide values close to normal. Larger-than-necessary volumes of air may cause gastric distention with associated risk of aspiration.

Bag-Valve-Mask Devices

Bag-valve-mask devices consist of a self-inflating bag (resuscitator bag) with a nonrebreathing valve mechanism and a soft mask that conforms to the tissues of the face; when connected to an oxygen supply, they deliver from 60 to 100% inspired oxygen (see also How To Do Bag-Valve-Mask Ventilation How To Do Bag-Valve-Mask (BVM) Ventilation Bag-valve-mask (BVM) ventilation is the standard method for rapidly providing rescue ventilation to patients with apnea or severe ventilatory failure. (See also Airway Establishment and Control... read more ). In the hands of experienced practitioners, a bag-valve-mask device provides adequate temporary ventilation in many situations, allowing time to systematically achieve definitive airway control. However, if bag-valve-mask ventilation is used for > 5 minutes, air is typically introduced into the stomach, and an nasogastric tube should be inserted to evacuate the accumulated air.

Head and neck positioning to open the airway

Head and neck positioning to open the airway

A: The head is flat on the stretcher; the airway is constricted. B: The ear and sternal notch are aligned, with the face parallel to the ceiling, opening the airway. Adapted from Levitan RM, Kinkle WC: , ed. 2. Wayne (PA), Airway Cam Technologies, 2007.

Jaw lift

Jaw lift

Several methods are used to select the proper size oropharyngeal airway, the most common being the distance between the corner of the patient’s mouth and the angle of the jaw.

Resuscitator bags are also used with artificial airways, including endotracheal tubes and supraglottic and pharyngeal airways. Pediatric bags have a pressure relief valve that limits peak airway pressures (usually to 35 to 45 cm water); practitioners must monitor the valve setting to avoid inadvertent hypoventilation. The relief valve can be shut off if necessary to provide sufficient pressure.

Laryngeal Mask Airways (LMA)

A laryngeal mask airway or other supraglottic airway can be inserted into the lower oropharynx to prevent airway obstruction by soft tissues and to create an effective channel for ventilation (see figure Laryngeal mask airway Laryngeal mask airway (LMA) If no spontaneous respiration occurs after airway opening and no respiratory devices are available, rescue breathing (mouth-to-mask or mouth-to-barrier device) is started; mouth-to-mouth ventilation... read more ). A variety of available LMAs allow passage of an endotracheal tube or a gastric decompression tube. As the name implies, these devices seal the laryngeal inlet (rather than the face-mask interface) and thus avoid the difficulty of maintaining an adequate face-mask seal and the risk of displacing the jaw and tongue. LMAs have become the standard rescue ventilation technique for situations in which endotracheal intubation cannot be accomplished, as well as for certain elective anesthesia cases and emergencies. Complications include vomiting and aspiration in patients who have an intact gag reflex, who are receiving excessive ventilation, or both.

There are numerous techniques for LMA insertion (see How to Insert a Laryngeal Mask Airway How To Insert a Laryngeal Mask Airway Laryngeal mask airway (LMA) ventilation is a method for providing rescue ventilation to unconscious patients or patients without a gag reflex that is technically easier than use of most other... read more ). The standard approach is to press the deflated mask against the hard palate (using the long finger of the dominant hand) and rotate it past the base of the tongue until the mask reaches the hypopharynx so that the tip then sits in the upper esophagus. Once in the correct position, the mask is inflated. Inflating the mask with half the recommended volume before insertion stiffens the tip, possibly making insertion easier. Newer mask versions replace the inflatable cuff with a gel that molds to the airway.

Although a laryngeal mask airway does not isolate the airway from the esophagus as well as an endotracheal tube, it has some advantages over bag-valve-mask ventilation:

  • It minimizes gastric inflation

  • It provides some protection against passive regurgitation

Newer versions of LMAs have an opening through which a small tube can be inserted to decompress the stomach.

The efficacy of the airway seal with an LMA, unlike endotracheal tubes, is not directly correlated with the mask inflation pressure. With endotracheal tubes, higher balloon pressure causes a tighter seal; with an LMA, overinflation makes the mask more rigid and less able to adapt to the patient’s anatomy. If the seal is inadequate, mask pressure should be lowered somewhat; if this approach does not work, a larger mask size should be tried.

In emergencies, laryngeal mask airways should be viewed as bridging devices. Prolonged placement, overinflation of the mask, or both may compress the tongue and cause tongue edema. Also, if noncomatose patients are given muscle relaxants Drugs to cause paralysis for intubation Pulseless and apneic or severely obtunded patients can (and should) be intubated without pharmacologic assistance. Other patients are given sedating and paralytic drugs to minimize discomfort... read more before LMA insertion (eg, for laryngoscopy), they may gag and possibly aspirate when such drugs wear off. Either the device should be removed (assuming ventilation and gag reflexes are adequate), or drugs should be given to eliminate the gag response and provide time for an alternative intubation technique.

Laryngeal mask airway (LMA)

Laryngeal mask airway (LMA)

The LMA is a tube with an inflatable cuff that is inserted into the oropharynx. A: The deflated cuff is inserted into the mouth. B: With the index finger, the cuff is guided into place above the larynx. C: Once in place, the cuff is inflated.

Some newer cuffs use a gel that molds to the airway rather than an inflatable cuff.

Endotracheal Tubes

An endotracheal tube is inserted directly into the trachea via the mouth or, less commonly, the nose. Endotracheal tubes have high-volume, low-pressure balloon cuffs to prevent air leakage and minimize the risk of aspiration. Cuffed tubes were traditionally used only in adults and children > 8 years; however, cuffed tubes are increasingly being used in infants and younger children to limit air leakage or aspiration (particularly during transport). Sometimes cuffs are not inflated or inflated only to the extent needed to prevent obvious leakage.

An endotracheal tube is the definitive method to secure a compromised airway, limit aspiration, and initiate mechanical ventilation in comatose patients, in patients who cannot protect their own airways, and in patients who need prolonged mechanical ventilation Overview of Mechanical Ventilation Mechanical ventilation can be Noninvasive, involving various types of face masks Invasive, involving endotracheal intubation Selection and use of appropriate techniques require an understanding... read more . An endotracheal tube also permits suctioning of the lower respiratory tract. Although drugs can be delivered via an endotracheal tube during cardiac arrest Cardiac Arrest Cardiac arrest is the cessation of cardiac mechanical activity resulting in the absence of circulating blood flow. Cardiac arrest stops blood from flowing to vital organs, depriving them of... read more , this practice is discouraged.

Other Airway and Respiratory Devices

Another class of rescue ventilation devices is laryngeal tube or twin-lumen airways (eg, Combitube®, King LT®). These devices use 2 balloons to create a seal above and below the larynx and have ventilation ports overlying the laryngeal inlet (which is between the balloons). As with laryngeal mask airways, prolonged placement and balloon overinflation can cause tongue edema (see How To Insert an Esophageal-Tracheal Double Lumen Tube (Combitube®) or a King Laryngeal Tube How To Insert an Esophageal-Tracheal Double Lumen Tube (Combitube®) or a King Laryngeal Tube The esophageal-tracheal double lumen tube (Combitube®) and the King laryngeal tube are supraglottic airway devices (also called retroglottic airway devices). (See also Airway Establishment and... read more ).

Click here for Patient Education
NOTE: This is the Professional Version. CONSUMERS: Click here for the Consumer Version
Professionals also read

Test your knowledge

How to Do the Heimlich Maneuver in the Conscious Adult or Child
The Heimlich maneuver should be used only when the airway obstruction is severe and life is endangered. Is it important NOT to interfere if the choking person can speak, cough forcefully, or breathe adequately. In addition, this maneuver is an absolute contraindication in which of the following individuals?
Download the Manuals App iOS ANDROID
Download the Manuals App iOS ANDROID
Download the Manuals App iOS ANDROID
Download the Manuals App iOS ANDROID
Download the Manuals App iOS ANDROID
Download the Manuals App iOS ANDROID

Also of Interest

Download the Manuals App iOS ANDROID
Download the Manuals App iOS ANDROID
Download the Manuals App iOS ANDROID
TOP